Electrode Amplifier User Manual
Order Code: EA-BTA
Use our Electrode Amplifier to collect data with almost any electrode that has a BNC connector. This includes electrodes from Vernier such as one of our pH, ISE, or ORP electrodes, or third-party electrodes, such as pH, ISE (ion-selective electrode), or ORP (oxidation-reduction potential). The Electrode Amplifier can produce an output in mV, pH (when using a pH electrode). You can also perform your own 2-point linear calibration.
Note:Vernier products are designed for educational use. Our products are not designed nor are they recommended for any industrial, medical, or commercial process such as life support, patient diagnosis, control of a manufacturing process, or industrial testing of any kind.
Compatible Software
Choose a platform below to see its compatibility requirements.
LabQuest
Interface | LabQuest App |
---|---|
LabQuest 3 | 全力支持1 |
LabQuest 2(discontinued) | 全力支持1 |
LabQuest(discontinued) | 全力支持1 |
Compatibility Notes
- Requires aBNC electrode
Computers
Software | |||
---|---|---|---|
Interface | 图形化的肛门ysis App for Computers Version 5.4 |
LoggerPro Version 3.16 |
Logger Lite Version 1.9.4 |
LabQuest Mini | 全力支持1 | 全力支持1 | 全力支持1 |
LabQuest 3 | 全力支持1 | 全力支持1 | Incompatible1 |
LabQuest 2(discontinued) | 全力支持1 | 全力支持1 | 全力支持1 |
LabQuest Stream | 全力支持12 | 全力支持1 | 全力支持12 |
Go!Link | 全力支持1 | 全力支持1 | 全力支持1 |
LabQuest(discontinued) | 全力支持1 | 全力支持1 | 全力支持1 |
LabPro(discontinued) | Incompatible | 全力支持1 | 全力支持1 |
Compatibility Notes
- Requires aBNC electrode
- Connect LabQuest Stream via USB. Wireless connection is not supported.
Chromebook
Software | |
---|---|
Interface | 图形化的肛门ysis App for Chrome Version 5.4 |
LabQuest Mini | 全力支持1 |
LabQuest 3 | 全力支持1 |
LabQuest 2(discontinued) | 全力支持1 |
LabQuest Stream | 全力支持12 |
Go!Link | 全力支持1 |
LabQuest(discontinued) | 全力支持1 |
Compatibility Notes
- Requires aBNC electrode
- Connect LabQuest Stream via USB. Wireless connection is not supported.
iOS
Software | ||
---|---|---|
Interface | 图形化的肛门ysis App for iOS Version 5.4 |
图形化的肛门ysis GW for iOS Version 4.0.6 |
LabQuest Stream | 全力支持1 | Partial support12 |
LabQuest 3 | 全力支持13 | 全力支持13 |
LabQuest 2(discontinued) | 全力支持13 | 全力支持13 |
Compatibility Notes
- Requires aBNC electrode
- Data collection will be in mV only. The pH calibration is not supported.
- iOS and Android™devices can only connect to LabQuest 2 or LabQuest 3 viaWireless Data Sharing.
Android
Software | ||
---|---|---|
Interface | 图形化分析为Android应用程序 Version 5.4 |
图形化的肛门ysis GW for Android Version 3.2 |
LabQuest Stream | 全力支持1 | Incompatible1 |
LabQuest 3 | 全力支持12 | 全力支持12 |
LabQuest 2(discontinued) | 全力支持12 | 全力支持12 |
Compatibility Notes
- Requires aBNC electrode
- iOS and Android™devices can only connect to LabQuest 2 or LabQuest 3 viaWireless Data Sharing.
Arduino
Software | |
---|---|
Interface | Arduino |
Vernier Arduino®Interface Shield | 全力支持 |
LabVIEW
Software | |
---|---|
Interface | NI LabVIEW |
SensorDAQ(discontinued) | 全力支持 |
Vernier myDAQ Adapter | 全力支持1 |
Go!Link | 全力支持 |
LabQuest Mini | 全力支持 |
LabQuest Stream | 全力支持 |
LabQuest 3 | 全力支持 |
LabQuest 2(discontinued) | 全力支持 |
LabQuest(discontinued) | 全力支持 |
Compatibility Notes
- You can only read the raw count/raw voltage output by this sensor. You must do the programming to convert to proper sensor units.
Texas Instruments
Software | |||||
---|---|---|---|---|---|
Interface | EasyData Version 2.4/4.0/5.2 |
DataMate Version 1.15 |
TI-84 SmartView | DataQuest Version 4.2 |
TI-Nspire Software |
EasyLink | 全力支持12 | Incompatible | 全力支持13 | 全力支持1 | 全力支持13 |
CBL 2 | 全力支持14 | 全力支持145 | Incompatible | Incompatible | Incompatible |
LabPro(discontinued) | 全力支持14 | 全力支持145 | Incompatible | Incompatible | Incompatible |
TI-Nspire Lab Cradle(discontinued) | Incompatible | Incompatible | Incompatible | 全力支持1 | 全力支持1 |
Compatibility Notes
- Requires aBNC electrode
- Use with TI-84 Plus calculators only.
- Requires anEasy to Go! adapter
- CBL 2 and LabPro interfaces cannot be used withTI-84 Plus CEcalculators.
- DataMate cannot be used with color screen TI-84 Plus calculators; useEasyDatawith these calculators.
开始
- Connect the sensor to the interface (LabQuest Mini, LabQuest 2, etc.).
- Start the appropriate data-collection software (LoggerPro, Logger Lite, LabQuest App, or Graphical Analysis 4) if not already running, and choose New from File menu. The software will identify the sensor and load a default data-collection setup. You are now ready to collect data.
If you are collecting data using a Chromebook™, mobile device such as iPad®or Android™ tablet, or a Vernier wireless interface, please see the following link for up-to-date connection information:
Specifications
Power |
7 mA @ 5VDC |
Input range |
–450 mV to +1100 mV |
Impedance |
100 M Ohm |
Gain |
2.2 V/V |
Offset |
120 V (nominal) |
Stored calibration (mV) |
|
Stored calibration (pH) |
|
Care and Maintenance
Do not wrap the cable tightly around the sensor for storage. Repeatedly doing so can irreparably damage the wires and is not covered under warranty.
How the Sensor Works
The Electrode Amplifier is a circuit that allows the millivolt output of an electrode to be monitored by an interface. The electrode is connected to the BNC connector on one end of the amplifier. The cable from the Electrode Amplifier connects to the interface.
The Electrode Amplifier will report values in units of pH. If an ORP or ISE electrode is attached, however, you can choose to read in units of mV. Custom linear 2-point calibrations can also be performed if desired.
Troubleshooting
For troubleshooting and FAQs, seem.cqlameng.com/til/1430
Repair Information
If you have watched the related product video(s), followed the troubleshooting steps, and are still having trouble with yourElectrode Amplifier, contact Vernier Technical Support at support@vernier.com or call 888-837-6437. Support specialists will work with you to determine if the unit needs to be sent in for repair. At that time, a Return Merchandise Authorization (RMA) number will be issued and instructions will be communicated on how to return the unit for repair.
Accessories/Replacements
Item | Order Code |
---|---|
NH4-BNC |
|
CA-BNC |
|
CL-BNC |
|
FPH-BNC |
|
GPH-BNC |
|
NO3-BNC |
|
ORP-BNC |
|
PH-BNC |
|
K-BNC |
Warranty
Vernier warrants this product to be free from defects in materials and workmanship for a period of five years from the date of shipment to the customer. This warranty does not cover damage to the product caused by abuse or improper use. This warranty covers educational institutions only.
Disposal
When disposing of this electronic product, do not treat it as household waste. Its disposal is subject to regulations that vary by country and region. This item should be given to an applicable collection point for the recycling of electrical and electronic equipment. By ensuring that this product is disposed of correctly, you help prevent potential negative consequences on human health or on the environment. The recycling of materials will help to conserve natural resources. For more detailed information about recycling this product, contact your local city office or your disposal service.
The symbol, shown here, indicates that this product must not be disposed of in a standard waste container.